Global Group

Best your Partner

제품 상세보기

제품 상세보기

장비명
Basic Qualification Kits
Wavelengths
200 - 650 nm

Basic Qualification Kits 

 

.  These kits have been designed to qualify UV-visible spectrophotometers over the wavelength and absorbance ranges commonly used in pharmaceutical analysis

 

 

기본구성

.  Basic Kit for EP2.2.25 compliance

Catalogue number: RM-EP20 [Kit Identity: RM-020610HLKISISNTX]

 

REFERENCE

TO QUALIFY

WAVELENGTH RANGE

Holmium cell

Wavelength accuracy

240 - 650 nm

Potassium Dichromate 20, 60 & 100 mg/l & blank cell

Absorbance accuracy and linearity, 0-1 A

235 350 nm

Sodium Iodide

Stray light, 220 nm

220 -370 nm

Potassium Iodide

Stray light, 250 nm

Sodium Nitrite

Stray light, 340, 370 nm

Toluene in Hexane

Resolution (bandwidth), 265-270nm

265-270 nm

 

 

 

 

 

 

 

.  Basic Kit for USP Chapter <857> compliance

 Catalogue number: RM-USP20 [Kit Identity: RM-020610HLACKISNTX]

 

REFERENCE

TO QUALIFY

WAVELENGTH RANGE

Holmium cell

Wavelength accuracy

240 - 650 nm

Potassium Dichromate 20, 60 & 100 mg/l & blank cell

Absorbance accuracy and linearity, 0-1 A

235 350 nm

Potassium dichromate

Absorbance accuracy, 1 A

430 nm

Potassium Iodide

Stray light, 220 nm

220 -370 nm

Acetone

Stray light, 300 nm

Sodium Nitrite

Stray light, 340 nm

Toluene in Hexane

Resolution (bandwidth), 265-270nm

265-270 nm

 

 

 

 

 

 

 

 

.  Basic Combination kit for EP and USP compliance

.  Catalogue number: RM-USPEP20 [Kit Identity: RM-020610HLACKISISNTX]

 

 

REFERENCE

TO QUALIFY

WAVELENGTH RANGE

Holmium cell

Wavelength accuracy

240 - 650 nm

Potassium Dichromate 20, 60 & 100 mg/l & blank cell

Absorbance accuracy and linearity, 0-1 A

235 350 nm

Potassium dichromate

Absorbance accuracy, 1 A (USP)

430 nm

Sodium Iodide

Stray light, 220 nm (EP)

220 -370 nm

Potassium Iodide

Stray light, 220 nm (USP), 250nm (EP)

Acetone

Stray light, 300 nm (USP)

Sodium Nitrite

Stray light, 340 nm (EP & USP), 370 nm (EP)

Toluene in Hexane

Resolution (bandwidth), 265-270nm

265-270 nm

 

 

 

 

 

 

 

 

.  Far UV extension kit – EP and USP compliance

.  Catalogue number: RM-06A12A24AREKC

 

REFERENCE

TO QUALIFY

WAVELENGTH RANGE

Cerium cell

Wavelength accuracy

200 -270 nm

Nicotinic acid 6, 12 & 24 mg/l

Absorbance accuracy and linearity, 0-1 A

210 - 270 nm

Potassium Chloride

Stray light, 200 nm

200 nm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 